Contact Us

If you still have questions or need technical support, please submit a request.
We’ll get back to you ASAP.

Please provide as much detail as possible, including your company name and a link to the page you need assistance with.

  • Contact Us
  • Log In
  • Home
  • Integrations
  • ATG Management

ATG Common Commands

Library of frequently used commands for most automatic tank gauges including name and description.

Written by Jess Hamilton

Updated at July 27th, 2024

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Titan Cloud Basics
    ATG Connectivity Activity Log Reports Administrative Console Setup & Implementation E-Files Inventory
  • Environmental Compliance
    Compliance Dashboard Important Dates Alarms Release Detection Cathodic Protection Remediation Operator Training Meter Calibration
  • Fuel Insight
    Inventory Variance Delivery Planning Frictionless Fueling
  • Facility Maintenance
  • Integrations
    API Documentation ATG Management PDI Integration for Inventory Reconciliation EMS Greenscan (SIR)
  • Advanced Facility Inspections and Enterprise Forms
    AFI Mobile App Advanced Facility Inspections Web View
  • Release Notes
    Titan Logistics (TFX) Release Notes Titan Cloud Edge Release Notes
+ More

Expand the sections below to view common commands for the VR TLS-350, VR TLS-450, FF TS-1000 in VR mode, FF TS-550 or EVO in VR mode, or the Incon 1000 Native.

 

VR TLS-350

Command Name Terminal Command Description
Basic Inventory 200 Current Inventory of the tanks
Current Alarms I10100 Current alarms as shown on the front panel
Sys Config Report I10200 Displays boards installed in the console.
Priority Alarm History I11100 List of active and cleared priority alarms.
Non-priority Alarm History I11200 List of active and cleared non-priority alarms.
Active Alarms I11300 List of active alarms, both priority and non
Cleared Alarm Report I11400 List of cleared alarms
Inventory Report I20100 Current Inventory of the tanks
In-Tank Leak Detect Report I20300 Most recent in-tank leak test results
In-Tank Shift Inventory Report I20400 Current shift inventory
Tank Release Detection History I20700 History of in-tank leak tests, with annual and periodic test results
In-Tank Leak Test Results Report I20800 Most recent tank test results
CSLD Results I25100 Results of CSLD tests
Liquid Sensors Results I30100 Current status of configured liquid sensors
Sensor Alarm Hist. Report I30200 Sensor alarm history, last three alarms for each configured liquid sensor
Smart Sensor Status Report I31500 Current status of configured smart sensors
Smart Sensor Status Alarm History I31600 Sensor alarm history, last three alarms for each configured smart sensor
Smart Sensor Install Report I33300 Shows when smart sensor installed, and the type
PLLD Results I37300 Passing results for PLLD tests
PLLD History I37400 History of PLLD tests
WPLLD Line Leak Test Results I38800 Passing results for Wireless PLLD tests
WPLLD Line Leak Test History I38900 History of Wireless PLLD tests
Tank Config I60100 Check if tanks are configured and turned on or off
Tank Product Label I60200 Product labels for each tank
Tank Full Volume I60400 Capacity of tank
Tank Leak Test Method I61100 Check if using tank leak tests, and if static or CSLD
Tank (Siphon) Manifolded Partners I61200 Check for manifolds programmed in gauge
Liquid Sensor Setup I70100 Check if Sensors are configured and turned on or off
Liquid Sensor Type I70200 Type of liquid sensor (Tri-state, Normally Closed, etc.)
Liquid Sensor Location Label I70300 Label of each liquid sensor
Smart Sensor Configuration I72100 Check if Sensors are configured and turned on or off
Smart Sensor Location Label I72200 Label of each smart sensor
Pressure Line Leak Setup I78000 Indicates which tank is tied to which PLLD.
Software Version I90200 Software version of the gauge
 
 

VR TLS-450

Command Name Terminal Command Description
Basic Inventory 200 Current Inventory of the tanks
Current Alarms I10100 Current alarms as shown on the front panel
Priority Alarm History I11100 List of active and cleared priority alarms.
Non-priority Alarm History I11200 List of active and cleared non-priority alarms.
Active Alarms I11300 List of active alarms, both priority and non
Cleared Alarm Report I11400 List of cleared alarms
Inventory Report I20100 Current Inventory of the tanks
In-Tank Leak Detect Report I20300 Most recent in-tank leak test results
In-Tank Shift Inventory Report I20400 Current shift inventory
Tank Release Detection History I20700 History of in-tank leak tests, with annual and periodic test results
In-Tank Leak Test Results Report I20800 Most recent tank test results
CSLD Results I25100 Results of CSLD tests
Liquid Sensors Results I30100 Current status of configured liquid sensors
Sensor Alarm Hist. Report I30200 Sensor alarm history, last three alarms for each configured liquid sensor
Smart Sensor Status Report I31B00 Current status of configured smart sensors
Smart Sensor Status Alarm History I31C00 Sensor alarm history, last three alarms for each configured smart sensor
PLLD Results I37300 Passing results for PLLD tests
PLLD History I37400 History of PLLD tests
Tank Config I60100 Check if tanks are configured and turned on or off
Tank Product Label I60200 Product labels for each tank
Tank Full Volume I60400 Capacity of tank
Tank Leak Test Method I61100 Check if using tank leak tests, and if static or CSLD
Tank (Siphon) Manifolded Partners I61200 Check for manifolds programmed in gauge
Liquid Sensor Setup I70100 Check if Sensors are configured and turned on or off
Liquid Sensor Type I70200 Type of liquid sensor (Tri-state, Normally Closed, etc.)
Liquid Sensor Location Label I70300 Label of each liquid sensor
Smart Sensor Configuration I72F00 Check if Sensors are configured and turned on or off
Smart Sensor Location Label I72E00 Label of each smart sensor
Pressure Line Leak Setup I78000 Indicates which tank is tied to which PLLD.
Software Version I90700 Software version of the gauge
 
 

FF TS-1000 in VR mode

*NOTE: This setup is limited on data available. Most known commands return computer format responses. 

Command Name Terminal Command Description
Basic Inventory 200 Current Inventory of the tanks
In-Tank Leak Detect Report 210 Most recent in-tank leak test results
Probe alarm history 240 Alarm history for the probes
System Info 930 System information
 
 

FF TS-550 or EVO in VR mode

*NOTE: Not all of these commands work on all software versions.

Command Name Terminal Command Description
Active Alarms I11300 List of active alarms, both priority and non
Liquid Sensors Results I30100 Current status of configured liquid sensors
Tank Release Detection History I20700 History of in-tank leak tests, with annual and periodic test results
Sensor Alarm Hist. Report I30200 Sensor alarm history, last three alarms for each configured liquid sensor
PLLD History I37400 History of PLLD tests
Tank Leak Test Method I61100 Check if using tank leak tests, and if static or CSLD
Software Version I90200 Software version of the gauge
 
 

Incon 1000 Native

*NOTE: This mode only has computer format responses, so it's best only to use to verify that the gauge is in Native mode. A Ctrl-C is needed after the string (^A1I003CCC^C)

Command Name Terminal Command Description
Active Alarms 1l003CCC Provides the active alarms.
 
 

 

For additional commands, please refer to the user manual or technical documentation provided by the hardware's manufacturer.

VR Tech Docs     FF Tech Docs

 

  • Integrations

    common atg atg commands 350 450 ts-1000 vr mode ts-550 evo incon 1000 native

    Was this article helpful?

    Yes
    No
    Give feedback about this article

    Related Articles

    • ATG Connectivity Troubleshooter
    • ATG Terminal Connect: Terminal Emulator Operating Guide
    • Reset Configuration Data from ATG
    • Is my ATG compatible with Titan Cloud?
    Titan Cloud Software

    At Titan Cloud, we connect people, equipment, and facilities to maximize the operational efficiency and minimize the environmental impact of fueling facilities around the world.

    twitter-logo linkedIn-logo youtube-logo
    • WHY TITAN CLOUD?
    • SOLUTIONS
      • Fuel Asset Optimization
        • Platform Overview
        • Compliance
        • Maintenance
        • Fuel
      • Customer Success
    • VALUE DRIVERS
      • Value Drivers
        • Customer Satisfaction
        • Risk Mitigation
        • Strategic Initiatives
        • Operational Efficiency
        • Revenue Opportunities
    • INDUSTRIES
      • Convenience
      • Fleet Operators
      • Service Providers
    • RESOURCES
      • Blog
      • Resource Library
        • Events
        • Case Studies
        • Videos
        • eBooks
        • Webinars
        • Datasheets
    • ABOUT
      • About
        • Leadership
      • Partners
      • Events
      • Careers
      • Newsroom
      • Contact

    © 2024 Titan Cloud Software. All Rights Reserved

    • Cookie Policy
    • Privacy Policy
    • Terms of Use

    Knowledge Base Software powered by Helpjuice

    Expand